PIR insulated composite roof and wall cladding
Supply-only prime PIR composite panels in Ireland run €22–€28/m² at 40 mm, €26–€34/m² at 60 mm, €31–€40/m² at 80 mm and €36–€48/m² at 100 mm ex VAT. Upgrading a full steel building from single-skin to 60–100 mm PIR adds €110 to €180/m² erected.
Factory-bonded polyisocyanurate sandwich panels for commercial workshops, warehouses and insulated garages in Ireland.
Free, no obligation. One local fabricator prices it, not five.
- €22–€48/m²prime PIR panel supply only, ex VAT
- 0.16 W/m²KPart L non-domestic roof U-value
- 0.21 W/m²KPart L non-domestic wall U-value
- Zero dripsvapour-sealed composite panel core

PIR panel thicknesses, U-values and Irish applications
40 mm PIR composite
- Typical U-value
- ~0.50–0.58 W/m²K
- Prime supply / m²
- €22–€28/m²
- Typical Irish application
- Domestic garages, classic-car stores and unheated workshops preventing condensation.
60 mm PIR composite
- Typical U-value
- ~0.35–0.38 W/m²K
- Prime supply / m²
- €26–€34/m²
- Typical Irish application
- Light commercial depots, heated hobby units and quiet rain-damped roofs.
80 mm PIR composite
- Typical U-value
- ~0.26–0.28 W/m²K
- Prime supply / m²
- €31–€40/m²
- Typical Irish application
- Heated trade workshops, low-energy industrial halls and commercial studios.
100 mm PIR composite
- Typical U-value
- ~0.20–0.22 W/m²K
- Prime supply / m²
- €36–€48/m²
- Typical Irish application
- Part L wall compliance (0.21 W/m²K); pair with 120–140 mm roof panels for 0.16 W/m²K.
Price my steel building
Four quick taps and our Irish guide price shows before we ask for a phone number. One local fabricator rings you, not five.
A commercial steel workshop, around 150 m² (80 to 200 m²), 60–100 mm PIR insulated shell erected: €60,000 to €84,000 (€400–€560/m²), ex VAT.
How the m² price is worked out
Figures reflect going Irish supply-and-erect rates ex VAT for CE-marked IS EN 1090-2 portal-frame buildings at typical 4 m to 6 m eaves. Shell rates cover fabricated columns, rafters, purlins, wind bracing, sheeting, gutters and erection on a prepared base. Insulated options add 60–100 mm PIR composite panels and roller doors. Slab options add excavated pad footings and a 150–200 mm power-floated C35 floor. Exposed Atlantic wind zones, rock excavation, three-phase ESB connections and BCAR fees are priced on survey.
Secret-fix facades, fire cores and airtight detailing
- Trapezoidal roof vs micro-rib / secret-fix walls. Box-profile through-fix panels suit trade depots; secret-fix flat or micro-rib wall panels hide fasteners on front-facing business-park facades.
- Mineral-wool core panels near boundaries. Where Fire Safety Certificate rules require 60-minute boundary fire resistance, rock-fibre / mineral-wool core composite panels replace PIR on that elevation.
- Factory-sealed side laps and ridge fillers. Butyl tape along roof lap joints and profiled foam fillers at eaves and ridge stop driving Atlantic rain and pass Part L 5.0 m³/(h·m²) airtightness tests.
- Coastal plastisol / PVDF coatings. Within 5 km of salt water, upgrade from standard polyester paint to 200-micron plastisol or coastal-rated coatings with stainless fixings.
Related steel building guides
Single-skin vs insulatedAnti-condensation non-drip fleece sheets versus PIR sandwich panels.
Roller shutters & rooflightsElectric industrial shutters, insulated sectional doors and GRP daylight panels.
Commercial workshops100 to 300 m² hot-rolled steel depots, roller shutters and power-floated floors.
Industrial warehouses300 to 1,000 m²+ high-eave logistics units, dock levellers and Part L specs.
Planning, FSC, DAC & BCARFull commercial planning, domestic 30 m² Class 3 cap, FSC, DAC and BCMS.
Steel building cost per m²Complete Irish €/m² breakdown from shell to insulated turnkey and civils.Key questions before ordering structural steel
What PIR thickness meets Part L for a heated commercial building in Ireland?
Under Technical Guidance Document L (Buildings other than Dwellings), elemental backstops are 0.21 W/m²K for walls (typically 100 mm PIR) and 0.16 W/m²K for pitched roofs (typically 120 to 140 mm PIR), verified in iSBEMie / NEAP.
How much does upgrading from single-skin to PIR cladding add to a build?
Across both walls and roof including flashings, fasteners and insulated gutters, expect +€110 to €180/m² of floor area ex VAT.
Should I use B-grade seconds PIR panels on a commercial build?
Surplus B-grade panels save 20–30% on non-regulated stores or DIY garages, though they carry no manufacturer thermal/fire warranty and do not pass BCAR certification on regulated commercial projects.
Do PIR insulated panels still need internal plasterboard or liner?
No. The inner steel sheet arrives pre-finished in bright food-safe white polyester, giving a clean, washable reflective workshop interior straight off the crane.
Every steel building page and engineering guide
Building types
Engineering & civils

Check your per-m² budget before a fabricator rings
Pick the building type, rough m² footprint and cladding or slab scope. When you want a written tender, your details go to a single Irish steel fabricator in your county.
